1. General Introduction
Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for differential, gage, and absolute pressure measurement. The coplanar platform enables seamless integration with manifolds, flow, and level solutions. It offers up to 5-year limited warranty, range down capability up to 150:1, support various communication protocol such as 4-20 mA HART, WirelessHART®, FOUNDATION fieldbus, Profibus, 1-5 V Low Power HART and etc.
Over 10 million Rosemount 3051 devices installed globally, providing reliable pressure readings in harsh environments, patented coplanar technology allows for direct mounting to multiple measurement applications, fully-assembled pressure, level and flow solutions arrive ready-to-install for improved reliability and performance, complete pressure assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation, 10-year installed stability and 150:1 range down produce reliable measurements and wide application flexibility, Local Operator Interface (LOI) enables quick commissioning and provides easy access to process and device information, SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
2. Range & sensor limits
Sensor Code | Minimum Span | Lower Range Limit (LRL) | Upper Range Limit (URL) | ||||||
3051CD | 3051CG | 3051CA | 3051CD | 3051CG | 3051CA | 3051CD | 3051CG | 3051CA | |
0 | 0.10 inH2O (0,24 mbar) | 0.10 inH2O (0,24 mbar) | N/A | –3.00 inH2O (–7,45 mbar) | N/A | N/A | 3.00 inH2O (7,45 mbar) | 3.00 inH2O (7,45 mbar) | N/A |
1 | 0.50 inH2O (1,24 mbar) | 0.50 inH2O (1,24 mbar) | 0.30 psi (20,68 mbar) | -25.00inH2O -62.16mbar | -25.00inH2O -62.16mbar | 0 psia (0bar) | 25.00 inH2O (62,16 mbar) | 25.00 inH2O (62,16 mbar) | 30psia (2,06 bar) |
2 | 1.67 inH2O (4,15 mbar) | 1.67 inH2O (4,15 mbar) | 1.00 psi (68,94 mbar) | –250.00 inH2O (–621,60 mbar) | –250.00 inH2O (–621,60 mbar) | 0 psia (0bar) | 250.00 inH2O (621,60 mbar) | 250.00 inH2O (621,60 mbar) | 150 psia (10,34 bar) |
3 | 6.67 inH2O (16,58 mbar) | 6.67 inH2O (16,58 mbar) | 5.33 psi (367,49 mbar) | –1000.00 inH2O (–2,48 bar) | 0.50 psia (34,47 mbar) | 0 psia (0bar) | 1000.00 inH2O (2,48 bar) | 1000.00 inH2O (2,48 bar) | 800 psia (55,15 bar) |
4 | 2.00 psi (137,89 mbar) | 2.00 psi (137,89 mbar) | 26.67 psi (1,83 bar) | –300.00 psi (–20,68 bar) | 0.50 psia (34,47 mbar) | 0 psia (0bar) | 300.00 psi (20,68 bar) | 300.00 psi (20,68 bar) | 4000 psia (275,79 bar) |
5 | 13.33 psi (919,01 mbar) | 13.33 psi (919,01 mbar) | N/A | – 2000.00 psi (–137,89 bar) | 0.50 psia (34,47 mbar) | N/A | 2000.00 psi (137,89 bar) | 2000.00 psi (137,89 bar) | N/A |
3. Basic code selection of 3051 Coplanar pressure transmitter
Main Code | Suffix Codes | Description | |||||||
3051C | Coplanar pressure transmitter | ||||||||
Measurement type | D | Differential | |||||||
G | Gage | ||||||||
A | Absolute | ||||||||
Pressure range (3051CD/3051CG/3051CA) | 1 | –62,16 to 62,16mbar/–62,16 to 62,16 mbar/ 0 to 2,06 bar | |||||||
2 | –621,60 to 621,60 mbar/–621,60 to 621,60 mbar/0 to 10,34 bar | ||||||||
3 | –2,48 to 2,48 bar/–0,97 to 2,48 bar/0 to 55,15 bar | ||||||||
4 | –20,68 to 20,68bar/–0,97 to 20,68 Bar/0 to 275,79 bar | ||||||||
5 | –137,89 to 137,89 bar/–0,97 to137,89 bar/N/A | ||||||||
0 | -7,46 to 7,46 mbar/N/A/N/A | ||||||||
Transmitter output | A | 4–20 mA with digital signal based on HART® Protocol | |||||||
F | FOUNDATION™ Fieldbus Protocol | ||||||||
W | PROFIBUS® PA Protocol | ||||||||
X | Wireless | ||||||||
M | Low-power, 1–5 Vdc with digital signal based on HART Protocol | ||||||||
Materials of construction (Process flange type/Flange material/Drain vent) | 2 | Coplanar/SST/SST | |||||||
3 | Coplanar/ Cast C-276 / Alloy C-276 | ||||||||
4 | Coplanar/ Alloy 400 / Alloy 400 or K-500 | ||||||||
5 | Coplanar/ Plated CS / SST | ||||||||
7 | Coplanar/ SST/ Alloy C-276 | ||||||||
8 | Coplanar/ Plated CS / Alloy C-276 | ||||||||
0 | Alternate process connection | ||||||||
Isolating diaphragm | 2 | 316L SST | |||||||
3 | Alloy C-276 | ||||||||
4 | Alloy 400 | ||||||||
5 | Tantalum | ||||||||
6 | Gold-plated alloy 400 | ||||||||
7 | Gold-plated 316 SST | ||||||||
O-ring | A | Glass-filled PTFE | |||||||
B | Graphite-filled PTFE | ||||||||
Sensor fill fluid | 1 | Silicone | |||||||
2 | Inert | ||||||||
Housing material/Conduit entry size | A | Aluminum/½–14 NPT | |||||||
B | Aluminum/M20 x 1.5 | ||||||||
E | Aluminum, ultra low copper/½–14 NPT | ||||||||
F | Aluminum, ultra low copper/M20 x 1.5 | ||||||||
J | SST/½–14 NPT | ||||||||
K | SST/M20 x 1.5 | ||||||||
P | Engineered polymer/No conduit entries | ||||||||
D | Aluminum/G½ | ||||||||
M | SST/ G½ | ||||||||
Optional codes | Optional codes [ As per table below] |
4. Optional order codes of 3051 Coplanar pressure transmitter
Wireless transmit rate, operating frequency, and protocol | |
WA3 | User Configurable Transmit Rate, 2.4 GHz WirelessHART |
Antenna and SmartPower | |
WP5 | Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately) |
Extended product warranty | |
WR3 | 3-year limited warranty |
WR5 | 5-year limited warranty |
Plantweb™ control functionality | |
A01 | FOUNDATION Fieldbus control function block suite |
Plantweb diagnostic functionality | |
DA0 | Loop Integrity HART Diagnostic |
D01 | FOUNDATION Fieldbus Diagnostics Suite |
Alternate flange | |
H2 | Traditional flange, 316 SST, SST drain/vent |
H3 | Traditional flange, alloy C, alloy C-276 drain/vent |
H4 | Traditional flange, cast alloy 400, alloy 400/K-500 drain/vent |
H7 | Traditional flange, 316 SST, alloy C-276 drain/vent |
HJ | DIN-compliant traditional flange, SST, 7/16-in. (10 mm) adapter/manifold bolting |
FA | Level flange, SST, 2-in. (51 mm), ANSI class 150, vertical mount 316 SST drain/vent |
FB | Level flange, SST, 2-in. (51 mm), ANSI Class 300, vertical mount 316 SST drain/vent |
FC | Level flange, SST, 3-in. (76 mm), ANSI Class 150, vertical mount 316 SST drain/vent |
FD | Level flange, SST, 3-in. (76 mm), ANSI Class 300, vertical mount 316 SST drain/vent |
FP | DIN level flange, SST, DN 50, PN 40, vertical mount 316 SST drain/vent |
FQ | DIN level flange, SST, DN 80, PN 40, vertical mount 316 SST drain/vent |
HK | DIN compliant traditional flange, SST, .4 in. (10 mm) adapter/manifold bolting 316 SST |
HL | DIN compliant traditional flange, SST, .5 in. (12 mm) adapter/manifold bolting 316 SST |
Manifold assembly | |
S5 | Assemble to Rosemount 305 Integral Manifold |
S6 | Assemble to Rosemount 304 Manifold or Connection System |
Integral mount primary element | |
S3 | Assemble to Rosemount 405 Compact Orifice Plate |
S4 | Assemble to Rosemount Annubar or Rosemount 1195 Integral Orifice |
Seal assemblies | |
S1 | Assemble to one Rosemount 1199 seal |
S2 | Assemble to two Rosemount 1199 seals |
Mounting bracket | |
B4 | Coplanar flange bracket, all SST, 2-in. pipe and panel |
B1 | Traditional flange bracket, CS, 2-in. pipe |
B2 | Traditional flange bracket, CS, panel |
B3 | Traditional flange flat bracket, CS, 2-in. (51 mm) pipe |
B7 | Traditional flange bracket, B1 with SST bolts |
B8 | Traditional flange bracket, B2 with SST bolts |
B9 | Traditional flange bracket, B3 with SST bolts |
BA | Traditional flange bracket, B1, all SST |
BC | Traditional flange bracket, B3, all SST |
Product certifications | |
E8 | ATEX Flameproof and Dust Certification |
I1 | ATEX Intrinsic Safety and Dust |
IA | ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only |
N1 | ATEX Type n Certification and Dust |
K8 | ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1) |
E4 | TIIS Flame-proof |
E5 | FM Explosion-proof, Dust Ignition-Proof |
I5 | FM Intrinsically Safe, Nonincendive |
IE | FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocol only |
K5 | FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2 |
C6 | CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 |
E6 | CSA Explosion-proof, Dust Ignition-proof, Division 2 |
I6 | CSA Intrinsic Safety |
K6 | CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) |
E7 | IECEx Flameproof, Dust Ignition-proof |
I7 | IECEx Intrinsic Safety |
N7 | IECEx Type n Certification |
K7 | IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7) |
E2 | INMETRO Flameproof |
I2 | INMETRO Intrinsic Safety |
IB | INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only |
K2 | INMETRO Flameproof, Intrinsic Safety |
Drinking water approval | |
DW | NSF drinking water approval |
Shipboard approvals | |
SBS | American Bureau of Shipping |
SBV | Bureau Veritas (BV) |
SDN | Det Norske Veritas |
SLL | Lloyds Register (LR) |
Custody transfer | |
C5 | Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range; contact an Emerson representative) |
Bolting material | |
L4 | Austenitic 316 SST bolts |
L5 | ASTM A 193, grade B7M bolts |
L6 | Alloy K-500 bolts |
Display and interface options | |
M4 | LCD display with LOI |
M5 | LCD display |
Calibration certificate | |
Q4 | Calibration Certificate |
QG | Calibration Certificate and GOST Verification Certificate |
QP | Calibration certification and tamper evident seal |
Material traceability certification | |
Q8 | Material Traceability Certification per EN 10204 3.1 |
Quality certification for safety | |
QS | Prior-use certificate of FMEDA data |
QT | Safety certified to IEC 61508 with certificate of FMEDA |
Configuration buttons | |
D4 | Analog zero and span |
DZ | Digital zero trim |
Transient protection | |
T1 | Transient protection terminal block |
Software configuration | |
C1 | Custom software configuration |
Low power output | |
C2 | 0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only) |
Gage pressure calibration | |
C3 | Gage calibration (Rosemount 3051ca4 only) |
Alarm levels | |
C4 | Analog output levels compliant with NAMUR recommendation NE 43, alarm high |
CN | Analog output levels compliant with NAMUR recommendation NE 43, alarm low |
CR | Custom alarm and saturation signal levels, high alarm |
CS | Custom alarm and saturation signal levels, low alarm |
CT | Rosemount standard low alarm |
Pressure testing | |
P1 | Hydrostatic testing with certificate |
Cleaning process area | |
P2 | Cleaning for special service |
P3 | Cleaning for < 1 ppm chlorine/fluorine |
Flange adapters | |
DF | ½–14 NPT flange adapter(s) |
Vent/drain valves | |
D7 | Coplanar flange without drain/vent ports |
DC | Ports left open - None |
Conduit plug | |
DO | 316 SST conduit plug |
RC¼ RC½ process connection | |
D9 | RC¼ flange with RC½ flange adapter - SST |
Max static line pressure | |
P9 | 4500 psig (310,26 bar) static pressure limit |
NACE certificate | |
Q15 | Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials |
Q25 | Certificate of Compliance to NACE MR0103 for wetted materials |
Cold temperature | |
BR5 | –58 °F (–50 °C) cold temperature operation |
BR6 | –76 °F (–60 °C) cold temperature operation |
HART revision configuration | |
HR5 | Configured for HART Revision 5 |
HR7 | Configured for HART Revision 7 |
5. Typical mounting & dimensions for 3051 Coplanar pressure transmitter with 3 way manifold 305RC3
6. Typical mounting & dimensions for 3051 Coplanar pressure transmitter with traditional flange
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
Tel: +971558915937
Fax: +971558915956
E-mail:
info@rostockgroup.com
technical@rostockgroup.com
commercial@rostockgroup.com
Get the latest special offers and discount information sent to your email address.
Copyright © Rostock Group Co.,Limited All Rights Reserved. Sitemap