1.General Introduction
ABB TTH200 Head-mount temperature transmitter is a 4 to 20mA HART protocol type which suitable for all standard requirements, which makes measurement more easier. It inputs the signal from RTD, resistance thermometer, thermocouples, resistance-type remote sensor and voltages, mV voltages, with SIL2/SIL3 approval in accordance with IEC 61508; While using the transmitter, the device fulfills the requirements in accordance with SIL 2. While using two redundant transmitters, the device fulfills the requirements in accordance with SIL 3.
2.Measuring Span & Accuracy
Sensor | Measuring range limits | Minimum span | Digital measuring accuracy (24-bit AD-converter) | DA measuring accuracy (16-bit DA) | |
Resistance thermometer/resistor | |||||
DIN IEC 60751 | Pt10 (a=0.003850) | -200 ... 850 °C (-328 … 1562 °F) | 10 °C (18 °F) | ± 0.80 °C (± 1.44 °F) | ± 0.05 % |
Pt50 (a=0.003850) | ± 0.16 °C (± 0.29 °F) | ± 0.05 % | |||
Pt100 (a=0.003850 | ± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
Pt200 (a=0.003850) | ± 0.24 °C (± 0.43 °F) | ± 0.05 % | |||
Pt500 (a=0.003850) | ± 0.16 °C (± 0.29 °F) | ± 0.05 % | |||
Pt1000 (a=0.003850) | ± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
JIS C1604 | Pt10 (a=0.003916) | -200 ... 645 °C (-328 ... 1193 °F) | 10 °C (18 °F) | ± 0.80 °C (± 1.44 °F) | ± 0.05 % |
Pt50 (a=0.003916) | ± 0.16 °C (± 0.29 °F) | ± 0.05 % | |||
Pt100 (a=0.003916) | ± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
MIL-T-24388 | Pt10 (a=0.003920 | -200 ... 850 °C (-328 ... 1562 °F) | 10 °C (18 °F) | ± 0.80 °C (± 1.44 °F) | ± 0.05 % |
Pt50 (a=0.003920) | ± 0.16 °C (± 0.29 °F) | ± 0.05 % | |||
Pt100 (a=0.003920) | ± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
Pt200 (a=0.003920) | ± 0.24 °C (± 0.43 °F) | ± 0.05 % | |||
Pt1000 (a=0.003920) | ± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
DIN 43760 | Ni50 (a=0.006180) | -60 ... 250 °C (-76 ... 482 °F) | 10 °C (18 °F) | ± 0.16 °C (± 0.29 °F) | ± 0.05 % |
Ni100 (a=0.006180) |
± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
Ni120 (a=0.006180) | ± 0.05 % | ||||
Ni1000 (a=0.006180) | ± 0.05 % | ||||
OIML R 84 | Cu10 (a=0.004270) | -50 ... 200 °C (-58 ... 392 °F) | 10 °C (18 °F) | ± 0.80 °C (± 1.44 °F) | ± 0.05 % |
Cu100 (a=0.004270) | ± 0.08 °C (± 0.14 °F) | ± 0.05 % | |||
Resistance measurement | 0 ... 500 Ω | 4 Ω | ± 32 mΩ | ± 0.05 % | |
0 … 5000 Ω | 40 Ω | ± 320 mΩ | ± 0.05 % | ||
Thermocouples / voltages | |||||
IEC 60584 | Type K (Ni10Cr-Ni5) | -270 … 1372 °C (-454 … 2502 °F) | 50 °C (90 °F) |
± 0.35 °C (± 0.63 °F) | ± 0.05 % |
Type J (Fe-Cu45Ni) | -210 … 1200 °C (-346 … 2192 °F) | ± 0.05 % | |||
Type N (Ni14CrSi-NiSi) | -270 … 1300 °C (-454 … 2372 °F) | ± 0.05 % | |||
Type T (Cu-Cu45Ni) | -270 ... 400 °C (-454 ... 752 °F) | ± 0.05 % | |||
Type E (Ni10Cr-Cu45Ni) | -270 … 1000 °C (-454 … 1832 °F) | ± 0.05 % | |||
Type R (Pt13Rh-Pt) | -50 … 1768 °C (-58 … 3215 °F) | 100 °C (180 °F) |
± 0.95 °C (± 1.71 °F) | ± 0.05 % | |
Type S (Pt10Rh-Pt) | ± 0.05 % | ||||
Type B (Pt30Rh-Pt6Rh) | -0 … 1820 °C (32 … 3308 °F) | ± 0.05 % | |||
DIN 43710 | Type L (Fe-CuNi) | -200 … 900 °C (-328 … 1652 °F) | 50 °C (90 °F) | ± 0.35 °C (± 0.63 °F) | ± 0.05 % |
Type U (Cu-CuNi) | -200 … 600 °C (-328 … 1112 °F) | ± 0.05 % | |||
ASTM E 988 | Type C | -0 … 2315 °C (32 … 4200 °F) | 100 °C (180 °F) | ± 1.35 °C (± 2.43 °F) | ± 0.05 % |
Type D | ± 0.05 % | ||||
Voltage measurement | -125 ... 125 mV | 2 mV | ± 12 μV | ± 0.05 % | |
-125 ... 1100 mV | 20 mV | ± 120 μV | ± 0.05 % |
3.Basic Code Selection of TTH200 Head-mount Temperature Transmitter
Main Code | Suffix Codes | Description | ||
TTH200 | TTH200 Head Mounted Temperature Transmitter | |||
Explosion Protection | Y0 | Without explosion protection | ||
E1 | ATEX Intrinsic Safety type of protection: Zone 0: II 1 G Ex ia IIC T6, Zone 1 (0): II 2 (1) G Ex [ia] ib IIC T6,Zone 1 (20): II 2 G (1D) Ex [iaD] ib IIC T6 | |||
E2 | ATEX Non-sparking type of protection: Zone 2: II 3 G Ex nA T6 | |||
H1 | IECEx Intrinsic Safety type of protection: Zone 0: Ex ia IIC T6, Zone 1 (0): Ex [ia] ib IIC T6, Zone 1 (20): Ex [iaD] ib IIC T6 | |||
L1 | FM Intrinsic Safety (IS): Class I, Div. 1+2, Groups A, B, C, D, Class I, Zone 0, AEx ia IIC T6 | |||
L2 | FM Non-incendive (NI): Class I, Div. 2, Groups A, B, C, D | |||
R1 | CSA Intrinsic Safety (IS): Class I, Div. 1+2, Groups A, B, C, D | |||
R2 | CSA Non-incendive (NI): Class I, Div. 2, Groups A, B, C, D | |||
G1 | GOST Russia - metrological approval | |||
G2 | GOST Russia - metrological approval and EAC-Ex, Ex i - Zone 0 | |||
G3 | GOST Kazakhstan - metrological approval | |||
T2 | GOST Kazakhstan - metrological approval and EAC-Ex, Ex i - Zone 0 | |||
C1 | Inmetro Ex ia IIC T6...T4 Ga, Ex ib [ia Ga] IIC T6...T4 Gb Exib [ia IIIC Da] IIC T6...T4 Gb | |||
Communication Protocol | H | HART, programmable, output signal 4 ... 20 mA | ||
Configuration | BS | Standard configuration | ||
BF | Customer-specific configuration, except user curve | |||
Optional Codes | /Optional codes |
4.Out Dimensions for TTH200 Head-mount Temperature Transmitter
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
Tel: +971558915937
Fax: +971558915956
E-mail:
info@rostockgroup.com
technical@rostockgroup.com
commercial@rostockgroup.com
Get the latest special offers and discount information sent to your email address.
Copyright © Rostock Group Co.,Limited All Rights Reserved. Sitemap