1.General Introduction
Yokogawa IR400 Infrared Gas Analyzer measure concentration of NO, SO2, CO2, CO, CH4 and O2 components in sample gas, NO, SO2, CO2, CO and CH4 are measured by the non-dispersive infrared method (NDIR), while O2 is measured by built-in paramagnetic sensor or external zirconia sensor. A maximum of 5 components including O2 (up to 4 components except for O2 measurement) are simultaneously measurable.The mass flow type twin detector of high sensitivity and reliability adopted in the infrared ray method detection unit makes the measurement hardly affected by interfering components. In addition, the IR400 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions. Optimum as an analyzer unit of measurement system for combustion exhaust gas from refuse incinerator and boiler, or gas from different industrial furnaces.
2.Measurable Gas Components and Ranges
Component | IR400 Infrared Gas Analyzer | |
Min. range | Max. range | |
NO | 0-50ppm | 0-5000ppm |
SO2 | 0-50ppm | 0-10vol% |
CO2 | 0-20ppm | 0-100vol% |
CO | 0-50ppm | 0-100vol% |
CH4 | 0-200ppm | 0-100vol% |
O2 (Built-in paramagnetic) | 0-5vol% | 0-25vol% |
O2 (Dedicated Zirconia) | 0-5vol% | 0-25vol% |
3.Model Selection
Main Code | Suffix Codes | Description | |||||||||||||||
IR400 | Infrared gas analyzer 19-inch rack mounting type with slide rail | ||||||||||||||||
Measurable Component | -A | 1st: NO | |||||||||||||||
-B | 1st: SO2 | ||||||||||||||||
-C | 1st: CO2 | ||||||||||||||||
-D | 1st: CO | ||||||||||||||||
-F | 1st: CH4 | ||||||||||||||||
-G | 1st: NO, 2nd: SO2 | ||||||||||||||||
-H | 1st: NO, 2nd: CO | ||||||||||||||||
-J | 1st: CO2, 2nd: CO | ||||||||||||||||
-K | 1st: NO, 2nd: SO2, 3rd: CO | ||||||||||||||||
-L | 1st: NO, 2nd: SO2, 3rd: CO2, 4th: CO | ||||||||||||||||
O2 Analyzer | N | Without O2 Analyzer | |||||||||||||||
1 | External Zirconia type O2 Sensor (ZX8D) | ||||||||||||||||
2 | External O2 Analyzer | ||||||||||||||||
3 | Built-in paramagnetic type O2 Sensor | ||||||||||||||||
1st Component 1st Range | V | 0-20ppm | |||||||||||||||
A | 0-50ppm | ||||||||||||||||
B | 0-100ppm | ||||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
1st Component 2nd Range | A | 0-50ppm | |||||||||||||||
B | 0-100ppm | ||||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
2nd Component 1st Range | A | 0-50ppm | |||||||||||||||
B | 0-100ppm | ||||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
2nd Component 2nd Range | B | 0-100ppm | |||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
3rd Component 1st Range | A | 0-50ppm | |||||||||||||||
B | 0-100ppm | ||||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
3rd Component 2nd Range | B | 0-100ppm | |||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
4th Component 1st Range | A | 0-50ppm | |||||||||||||||
B | 0-100ppm | ||||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
4th Component 2nd Range | B | 0-100ppm | |||||||||||||||
C | 0-200ppm | ||||||||||||||||
D | 0-250ppm | ||||||||||||||||
W | 0-300ppm | ||||||||||||||||
E | 0-500ppm | ||||||||||||||||
F | 0-1000ppm | ||||||||||||||||
G | 0-2000ppm | ||||||||||||||||
H | 0-5000ppm | ||||||||||||||||
J | 0-1% | ||||||||||||||||
K | 0-2% | ||||||||||||||||
L | 0-3% | ||||||||||||||||
M | 0-5% | ||||||||||||||||
P | 0-10% | ||||||||||||||||
Q | 0-20% | ||||||||||||||||
R | 0-40% | ||||||||||||||||
S | 0-50% | ||||||||||||||||
T | 0-70% | ||||||||||||||||
U | 0-100% | ||||||||||||||||
N | Not available | ||||||||||||||||
O2 Analyzer 1st Range | 1 | 0-5% | |||||||||||||||
2 | 0-10% | ||||||||||||||||
3 | 0-25% | ||||||||||||||||
N | Not available | ||||||||||||||||
O2 Analyzer 2nd Range | 2 | 0-10% | |||||||||||||||
3 | 0-25% | ||||||||||||||||
N | Not available | ||||||||||||||||
Output | -4 | 4-20mA DC, non-isolation | |||||||||||||||
-1 | 0-1 V DC, non-isolation | ||||||||||||||||
Piping | R | Rc1/4 | |||||||||||||||
T | 1/4 NPT | ||||||||||||||||
Indication, Power Cable | W | Japanese, Power Cable: rated voltage 125 V AC | |||||||||||||||
L | English, Power Cable: rated voltage 125 V AC (UL) | ||||||||||||||||
C | English, Power Cable: rated voltage 250 V AC (CEE) | ||||||||||||||||
Options | /K | With O2 correction and O2 average value | |||||||||||||||
/A | Peak count alarm output | ||||||||||||||||
/C | RS-232C communication | ||||||||||||||||
/P | Analyzer internal purging | ||||||||||||||||
/R | With dedicated cable |
4.Basic System Configuration
5.Measure Principle
6.External Dimensions
Address: P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
Tel: +971558915937
Fax: +971558915956
E-mail:
info@rostockgroup.com
technical@rostockgroup.com
commercial@rostockgroup.com
Get the latest special offers and discount information sent to your email address.
Copyright © Rostock Group Co.,Limited All Rights Reserved. Sitemap